Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 31(22): 36273-36280, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-38017782

RESUMO

The integration of compact high-bandwidth III-V active devices in a scalable manner is highly significant for Silicon-on-insulator (SOI) photonic integrated circuits. To address this, we demonstrate the integration of pre-fabricated 21 × 57 µm2 InGaAs photodetector (PD) coupons with a thickness of 675 nm to a 500 nm SOI platform using a direct bonding micro-transfer printing process. The common devices are coupled to the Si waveguides via butt, grating and evanescent coupling schemes with responsivities of 0.13, 0.3 and 0.6 A/W respectively, in line with simulations. The thin device facilitates simplified high-speed connections without the need for an interlayer dielectric. A back-to-back data communication rate of 50 Gb/s is achieved with on-off keying and with post processing of four-level pulse-amplitude modulation (PAM4) 100 Gb/s is realized. Potentially, around 1 million devices per 75 mm InP wafer can be attained. The integration of compact PDs exhibited in this work can be extended to modulators and lasers in the future.

2.
Opt Express ; 29(10): 14438-14451, 2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-33985167

RESUMO

We demonstrate high-speed silicon modulators optimized for operating at the wavelength of 2 µm. The Mach-Zehnder interferometer (MZI) carrier-depletion modulator with 2 mm phase shifter has a single-arm modulation efficiency (Vπ ·Lπ) of 2.89 V·cm at 4 V reverse bias. Using a push-pull configuration it operates at a data rate of 25 Gbit/s OOK with an extinction ratio of 6.25 dB. We also proposed a mathematically-analysed streamlined IMDD PAM-4 scheme and successfully demonstrated a 25 Gbit/s datarate PAM-4 with the same 2 mm modulator. A Michelson interferometer carrier-depletion modulator with 0.5 mm phase shift length has also been shown with modulation efficiency (Vπ ·Lπ) of 1.36 V·cm at 4 V reverse bias and data rate of 20 Gbit/s OOK. The Michelson interferometer modulator performs similarly to a Mach-Zehnder modulator with twice the phase shifter length.

3.
Europace ; 19(5): 874-880, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27207815

RESUMO

AIMS: Longer procedural time is associated with complications in radiofrequency atrial fibrillation ablation. We sought to reduce ablation time and thereby potentially reduce complications. The aim was to compare the dimensions and complications of 40 W/30 s setting to that of high-power ablations (50-80 W) for 5 s in the in vitro and in vivo models. METHODS AND RESULTS: In vitro ablations-40 W/30 s were compared with 40-80 W powers for 5 s. In vivo ablations-40 W/30 s were compared with 50-80 W powers for 5 s. All in vivo ablations were performed with 10 g contact force and 30 mL/min irrigation rate. Steam pops and depth of lung lesions identified post-mortem were noted as complications. A total of 72 lesions on the non-trabeculated part of right atrium were performed in 10 Ovine. All in vitro ablations except for the 40 W/5 s setting achieved the critical lesion depth of 2 mm. For in vivo ablations, all lesions were transmural, and the lesion depths for the settings of 40 W/30 s, 50 W/5 s, 60 W/5 s, 70 W/5 s, and 80 W/5 s were 2.2 ± 0.5, 2.3 ± 0.5, 2.1 ± 0.4, 2.0 ± 0.3, and 2.3 ± 0.7 mm, respectively. The lesion depths of short-duration ablations were similar to that of the conventional ablation. Steam pops occurred in the ablation settings of 40 W/30 s and 80 W/5 s in 8 and 11% of ablations, respectively. Complications were absent in short-duration ablations of 50 and 60 W. CONCLUSION: High-power, short-duration atrial ablation was as safe and effective as the conventional ablation. Compared with the conventional 40 W/30 s setting, 50 and 60 W ablation for 5 s achieved transmurality and had fewer complications.


Assuntos
Queimaduras por Corrente Elétrica/prevenção & controle , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/cirurgia , Animais , Queimaduras por Corrente Elétrica/etiologia , Queimaduras por Corrente Elétrica/patologia , Átrios do Coração/lesões , Átrios do Coração/patologia , Sistema de Condução Cardíaco/lesões , Sistema de Condução Cardíaco/patologia , Técnicas In Vitro , Duração da Cirurgia , Doses de Radiação , Ovinos , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...